NOVOTEST - Ultrasonic Thickness Gauge UT-1M-ST Brand : Novotest Model : UT-1M-ST Product Descriptions This special version of the thickness gauge, housed in a durable aluminum enclosure, is designed for extreme conditions where the device might be dropped or damaged. Its robust profile withstands high static and dynamic compression, allowing for ¡°careless¡± use. Product Features Unique additional protection of metal housing Material selection and automatic setting of ultrasound velocity Large graphic display of high contrast and backlight Display of measured thickness in mm and inches Convenient menu in the device Wide choice of UT probes with preset settings in the device Modes of statistical processing of measurements Ability to restore factory calibrations Ability to adjust all parameters of the acoustic path Ability of further adjusting the user gain (¡À20 Db) directly from the measurement mode Wide measurement range (0.4 to 1500 mm and more) Available probes 1.25-10 MHz: – 1.25MHz probe (echo) 20/2 for substantial thicknesses or materials with exceptionally high signal attenuation – 2.0MHz probe (echo) 20/2 for large thicknesses or materials with high signal attenuation – 2.5MHz probe (echo) 12/2 for thick samples – 5MHz probe (echo) 10/2 for a wide range of basic samples – 10MHz probe (echo) 6/2 for thin samples – 10MHz probe (echo) 2§ç3 for products of complex shapes, usually turbine blades – 5MHz high-temperature probe (echo) 10/2 for heated samples up to 250 ¡ã§³/482 ¡ãF – 2.5MHz probe (echo-echo) 12/2 for through coating – 5MHz probe (echo-echo) 10/2 for through coating – 10MHz probe (echo-echo) 6/2 for through coating – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 10 m cable – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 20 m cable – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 30 m cable B-scan and control modes Through-coating (echo-echo) mode Threshold setting with automatic alarm Saving the settings for different probes Compatibility with probes of other manufacturers V-path correction and TVG adjusting for the user¡¯s probes Measurement storage and PC software PC cable connection: – Online – NOVOTEST.INFO/USB-connect – Offline – NOVOTEST USB-Connect Technical Specifications Probe type range for steel, mm: Probe 10MHz – P112-10-2¡Á3 Probe 10MHz – P112-10-6 / 2 Probe 5MHz – P112-5-10 / 2 Probe 2,5MHz – P112-2,5-12 / 2 Probe 2MHz – P112-2-20 / 2 Probe 1,25MHz – P112-1.25-20 / 2 0.4-15 0.45-300 0.8-500 2.5-1000 3-1200 4-1500 Probe dimensions, mm: Probe 10MHz – P112-10-2¡Á3 Probe 10MHz – P112-10-6 / 2 Probe 5MHz – P112-5-10 / 2 Probe 2,5MHz – P112-2,5-12 / 2 Probe 2MHz – P112-2-20 / 2 Probe 1,25MHz – P112-1.25-20 / 2 4¡Á9¡Á60 D12¡Á15 D17¡Á20 D20¡Á21 D30¡Á28 D30¡Á35 Dimensions of probe contact area/crystal, mm: Probe 10MHz – P112-10-2¡Á3 Probe 10MHz – P112-10-6 / 2 Probe 5MHz – P112-5-10 / 2 Probe 2,5MHz – P112-2,5-12 / 2 Probe 2MHz – P112-2-20 / 2 Probe 1,25MHz – P112-1.25-20 / 2 2¡Á7/2¡Á3 D9/D6 D14/D10 D16/D12 D24/D20 D24/D20 Optional probes: 5MHz high-temperature probe (echo) 10/2 2,5MHz probe (echo-echo) 12/2 for through coating 5MHz probe (echo-echo) 10/2 for through coating 10MHz probe (echo-echo) 6/2 for through coating 5MHz probe (echo-echo) 10/2 for through coating, underwater, 10 m cable 5MHz probe (echo-echo) 10/2 for through coating, underwater, 20 m cable 5MHz probe (echo-echo) 10/2 for through coating, underwater, 30 m cable range 0,8 – 300 mm, surface temperature up to 250 ¡ã§³/482 ¡ãF range 6 – 30 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 2 – 12 mm, coating thickness range – up to 0,6 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm Compatible probe types Ultrasonic, dual-element, longitudinal waves (including probes of other manufacturers) Compatibility with Active EMAT Transducer EMAT-A1 No Probe calibrations (V-path, TVG, etc.) factory for NOVOTEST probes users for probes of other manufacturers Probe cable connector type 2 Lemo 00 Probe cable length, m 1,2 Measurement scales mm (m/s) inch (inch/¦Ìs) Measurement resolution, mm/inch 0.01/0.001 (0.01/0.0001 by request) Basic measurement accuracy, mm ¡À (0,01 T+0.05) (*For range 0.8 – 300 mm) Gain range, dB ¡À 20 Response time, with no more than, s 1 Setting range of the ultrasonic velocity, m / s 1000-17000 Preset velocities for materials Steel (8 different grades), Aluminum, Iron, Cast Iron, Zinc, Chromium, Copper, Brass, Bronze, Silver, Gold, Nickel, Tungsten, Tin, Lead, Molybdenum, Manganese, Magnesium, Rubber, Polystyrene, Plexiglas, Capron, Caprolon, ED-5, Ebonite, Porcelain, Teflon, Textolite, Silicate Glass, Acrylic glass, User Operating modes Normal B-scan Control mode Standards ASTM E797 EN 14127 EN15317 Body type / Dust and moisture protection level Plastic, with shockproof silicone case Standard for shop and field operation IP54 Calibration thickness block on the body 6 mm (Steel/~6080 m/s) PC cable connection Online – NOVOTEST.INFO/USB-connect Offline – NOVOTEST USB-Connect Wireless connection with Android gadgets via NOVOTEST Lab App No Storage capacity of measurement results 128 Measurement archives Device menu PDF Excel (CSV) Menu languages English, Spanish, Ukrainian, Russian (other languages optional) Operating environment Temperature:-20¡ãC~50¡ãC Humidity: 30%~80%R.H. Power supply DC 3V (2 pcs standard batteries AA) Time of continuous work hours, not less, h 25 Charging External charger for 2pcs AA batteries Weight of electronic unit with batteries, no more, kg 0.25 Overall dimensions, mm 130x90x40 Package weight, kg 1.5 Package dimensions, cm 33*27*10 Documents Operation manual UT-1M Quick guide UT-1M/-ST Brochure UT-1M/-2A Country of origin Made in Ukraine (Europe) Warranty Basic – 12 months for electronic unit – 6 months for probes Extended (optional) – up to 3 years General comparative chart of all models NOVOTEST ultrasonic thickness gauges (without UT-3M-EMAT) Model name UT-2A UT-1M UT-1M-IP UT-1M-ST Measuring thicknesses range for steel, mm 0,4 – 1500 (depends on probe) 0,45 – 1500 (depends on probe) Resolution, mm 0,01 Basic measurement accuracy, mm ¡À (0,01*T+0,05) Basic probes / range for steel 2,5 MHz / 2,5 – 1000 mm 5 MHz / 0,8 – 300 mm 10 MHz / 0,45 – 75 mm Optional probes / range for steel 1,25 MHz / 4 – 1500 mm 2 MHz / 3 – 1200 mm High-temperature 5MHz (up to 250 ¡ã§³) / 0,8 – 300 mm Echo-Echo 5MHz for through-coating measurements / 3,5 – 26 mm Compatibility with Active EMAT Transducer EMAT-A1 Yes No Compatible probe types Dual-element Single-element Dual-element Operating modes Normal A-scan B-scan Manual mode Control mode Normal B-scan Control mode Measurement methods Echo Echo-Echo Peak-Peak Zero-crossing Echo Echo-Echo Measurement units mm inch Display Color, 3,5 inch, 480*320 Monochrome, 2,5 inch, 128*64 Menu languages English Ukrainian Russian (other languages optional) English Spanish Ukrainian Russian (other languages optional) Body type/ Dust and moisture protection level Metal, durable /Standard for shop and field operation Plastic, with shockproof silicone case / Standard for shop and field operation Plastic, sealed /High – optionally water immersion up to 1m deep for 30 min Metal, durable /Standard for shop and field operation Saving of the settings for different probes Yes Compatibility with probes of other manufacturers Yes V-path correction and TVG adjusting for the user¡¯s probes Yes Storage of measurement results 7000 and more (Limited only by the memory card) 128 128 128 PC cable connection (via www.novotest.info) Yes Smartphone Wireless connection (via NOVOTEST Lab) No Optional Optional No Charger type Any USB socket (charger adapter, PC, power bank, etc.) External charger for batteries Any USB socket (charger adapter, PC, power bank, etc.) External charger for batteries Battery Built-in Li-ion 2pcs standard §¡§¡ batteries 3pcs standard §¡§¡ batteries 2pcs standard §¡§¡ batteries Electronic unit weight, no more, kg 0,5 0,25 0,35 0,35 Dimensions (L x W x H), mm 165x90x50 122§ç76§ç37 160§ç90§ç28 130§ç90§ç40 Minimum time of continuous work, h 10 25 25 25 Operating temperature range, ¡ã C -20 to +40
read more