- Color & Paint Coating Measurement
- Dimensional Measurement
- Electrical & Electronic Meter
- Electrostatics (ESD) , Ionizer & Resistivity Meter
- Environmental & Weather Aging Testing
- Gas Measurement
- Handling & Cutting Tools
- Hardness Testing
- Laboratory Equipments
- Levelling Angle Gauges
- Magnetic Testing
- Medical Equipment
- Metallography
- Microscope, Magnifier & Visual Inspection
- Paper & Film Packaging Testing
- Pressure & Flow
- Rubber & Glove Testing
- Storage Dry Cabinet
- Temperature, Humidity & Moisture
- Tensile & Tension Torque/Force
- Ultrasonic NDT Testing
- Vise & Holder
- Water Analysis Meter
- Weighing
- Others
HUDA 每 Temperature & Humidity Chamber HUD-E702 Series
Previous | 15 / 682 | Next |
HUDA – Temperature & Humidity Chamber HUD-E702 Series
Brand: HUDA
Model: HUD-E702-100, HUD-E702-150, HUD-E702-225, HUD-E702-408, HUD-E702-1000
Introduction:
Temperature Humidity Test Chamber, also known as Climatic Chamber or Environmental Test Chamber.
It is wildly used for quality assurance and reliability testing in fields like the electronics, electrical appliances, mobile phones, communications, vehicles, plastics, metals, engineering, pharmaceutical, aerospace.
Specification:
Brand: HUDA
Model: HUD-E702-100, HUD-E702-150, HUD-E702-225, HUD-E702-408, HUD-E702-1000
Introduction:
Temperature Humidity Test Chamber, also known as Climatic Chamber or Environmental Test Chamber.
It is wildly used for quality assurance and reliability testing in fields like the electronics, electrical appliances, mobile phones, communications, vehicles, plastics, metals, engineering, pharmaceutical, aerospace.
Specification:
Model | HUD-E702-100 | HUD-E702-150 | HUD-E702-225 | HUD-E702-408 | HUD-E702-1000 |
Internal dimension | 400*500*500mm | 500*600*500mm | 500*750*600mm | 600*850*800mm | 1000*1000*1000mm |
External dimension | 740*1700*1380mm | 870*1800*1430mm | 870*1890*1530mm | 1070*1900*1630mm | 1240*1970*2230mm |
Temperature range | -60⊥/-40⊥/-20⊥‵+150⊥ | ||||
Temperature fluctuations | ≤±0.5⊥ ㄗwithout load and temperature stableㄘ | ||||
Temperature uniformity | ≤4⊥ ㄗwithout load and temperature stableㄘ | ||||
Temperature deviation | ≤±2⊥ ㄗwithout load and temperature stableㄘ | ||||
Heating rate | +25⊥‵+150⊥≥40minㄗwithout loadㄘ | ||||
Cooling rate | +25⊥‵ -70⊥≥80min ㄗwithout loadㄘ | ||||
Power | 3 phase, AC380V, 50Hz, about 5KW | ||||
Humidity range | Temperature : +20⊥‵+85⊥ㄛHumidityㄩ 20%‵98%RH | ||||
Humidity deviation |
1﹜≥75%RH : ≤±3%RH˙ 2﹜≤75%RHㄩ≤±5%RH |
||||
Noise | ≤75db, measured from one meter in front of door, at 1.2meter height. |