HANDPI - LX-F Shore Durometer Sponge Foam Hardness Tester
Previous | 4 / 64 | Next |
HANDPI - LX-F Shore Durometer Sponge Foam Hardness Tester
Brand: HANDPI
Model: LX-F
Introduction:
LX-F type sponge durometer is suitable for the determination of soft foam, polyurethane foam rubber products hardness.
it will be different with the other hardness tester In the aspects of using. When using, the presser foot directly contact to the sample, and see its own weight as force measurement load.
Specification:
The Method of Use:
1. Handheld the middle of the instrument, located the hardness tester gently on the plane specimens which is bigger than presser foot (or specimen).
2. Reading out the value in 1 seconds when durometers’ presser foot contact with the sample smoothly.
3. The tick of pointers is the hardness value of sample (specimen).
4. In order to improving the accuracy of measurement, you should put the sample on a flat plate glass or plate.
5. Each measuring point should be measured only one time, the measuring point at a distance of more than 25mm of different parts from the same sample.
should be more than 5 points.
6. To take the average of measurement results, namely it’s the hardness value of the materials.
Brand: HANDPI
Model: LX-F
Introduction:
LX-F type sponge durometer is suitable for the determination of soft foam, polyurethane foam rubber products hardness.
it will be different with the other hardness tester In the aspects of using. When using, the presser foot directly contact to the sample, and see its own weight as force measurement load.
Specification:
Model | LX-F |
Scope of pressure needle route | 0 ~ 2.5millimeters |
The scale value | 0-100 degrees |
The force of pressure needle end | 550mN~4300mN(56~438.5g) |
The Method of Use:
1. Handheld the middle of the instrument, located the hardness tester gently on the plane specimens which is bigger than presser foot (or specimen).
2. Reading out the value in 1 seconds when durometers’ presser foot contact with the sample smoothly.
3. The tick of pointers is the hardness value of sample (specimen).
4. In order to improving the accuracy of measurement, you should put the sample on a flat plate glass or plate.
5. Each measuring point should be measured only one time, the measuring point at a distance of more than 25mm of different parts from the same sample.
should be more than 5 points.
6. To take the average of measurement results, namely it’s the hardness value of the materials.