- Color & Paint Coating Measurement
- Dimensional Measurement
- Electrical & Electronic Meter
- Electrostatics (ESD) , Ionizer & Resistivity Meter
- Environmental & Weather Aging Testing
- Gas Measurement
- Handling & Cutting Tools
- Hardness Testing
- Laboratory Equipments
- Levelling Angle Gauges
- Magnetic Testing
- Medical Equipment
- Metallography
- Microscope, Magnifier & Visual Inspection
- Paper & Film Packaging Testing
- Pressure & Flow
- Rubber & Glove Testing
- Storage Dry Cabinet
- Temperature, Humidity & Moisture
- Tensile & Tension Torque/Force
- Ultrasonic NDT Testing
- Vise & Holder
- Water Analysis Meter
- Weighing
- Others
HANNA - Ammonia Low Range Reagents 100 tests (HI-93700-01)
Previous | 290 / 497 | Next |
HANNA - Ammonia Low Range Reagents (HI-93700-01)
Brand: Hanna
Code No: (HI-93700-01)
Product Description:
The HI-93700-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample. By simply adding 4 drops from each bottle of HI93700-01 reagent set to the sample, the reaction between ammonia and reagents causes a yellow tint in the sample will take place. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in ppm (mg/L) of either ammonia-nitrogen (NH3-N), ammonia or ammonium based on meter and setting being used. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 ppm ammonia-nitrogen.
Specifications:
Brand: Hanna
Code No: (HI-93700-01)
Product Description:
The HI-93700-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample. By simply adding 4 drops from each bottle of HI93700-01 reagent set to the sample, the reaction between ammonia and reagents causes a yellow tint in the sample will take place. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in ppm (mg/L) of either ammonia-nitrogen (NH3-N), ammonia or ammonium based on meter and setting being used. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 ppm ammonia-nitrogen.
Specifications:
Package | dropper bottles ''A'' and ''B'' |
Quantity | 100 tests |
Method | adaptation of the ASTM Manual of Water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample. |