HIOKI-DC Signal Source SS7012
Previous | 447 / 498 | Next |
HIOKI-DC Signal Source SS7012
Brand : Hioki
Model : SS7012
Description :
DC Voltage and Current Signal Generator and Tester for Routine Maintenance of Standard Devices. The HIOKI DC Signal Source SS7012 can be used not only for instrumentation system (4-20 mA) maintenance, but also for maintaining and servicing thermostatic devices, distributors, and industrial meters, as well as for evaluating electronic circuits and devices, and for production facility maintenance.
Specification :
Basic Specifications (Generation Functions) :
(Measurement Functions) :
(General Function) :
Brand : Hioki
Model : SS7012
Description :
DC Voltage and Current Signal Generator and Tester for Routine Maintenance of Standard Devices. The HIOKI DC Signal Source SS7012 can be used not only for instrumentation system (4-20 mA) maintenance, but also for maintaining and servicing thermostatic devices, distributors, and industrial meters, as well as for evaluating electronic circuits and devices, and for production facility maintenance.
Specification :
Basic Specifications (Generation Functions) :
Circuit method |
Bipolar sink and source |
Constant voltage |
2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution) 25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution) |
Constant current |
25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution) |
Thermoelectric power generation |
K: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable |
K: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable | |
Standard resistance (Rs) |
100 Ω (±0.2 Ω) |
Automatic generation |
Number of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode) |
(Measurement Functions) :
Voltage |
2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance) 25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance) |
Current | 25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, smaller than 30 Ω input resistance) |
Temperature | -25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184) |
Sampling Rate | Approx. 1.67 times/sec |
(General Function) :
Additional Functions | Zero adjustment, Overflow display, USB communication, Monitor |
Power Supply |
AC adapter 9445-02/-03 (100 to 240 V AC 50/60 Hz, 9 VA), Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170 minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA |
Dimensions and Mass | 104 mm (4.09 in) W × 180 mm (7.09 in) H × 58 mm (2.28 in) D, 660 g (23.3 oz) (including LR6 × 4 batteries) |
Accessories | Input cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline battery ×4, Instruction manual ×1 |