RENISHAW 每 TP20/TP20 NI Modular Probes
Previous | 195 / 271 | Next |
RENISHAW – TP20/TP20 NI Modular Probes
Brand: Renishaw
TP20 probe body
The TP20 probe body houses one half of the highly repeatable magnetic kinematic coupling that attaches the stylus module and body. The body also contains a magnetic proximity switch to inhibit triggering of the probe during automatic module changing with MCR20.
Note: If the probe is operated close to magnetize parts/clamping etc, the probe trigger may become inhibited. Countermeasures include the use of long styli, stylus extensions or body orientation to increase the distance to the magnetic source. Alternatively, use the TP20 NI probe body.
TP20 NI probe body
The TP20 NI probe differs from the TP20 body in that it is not affected by magnetic fields. However, the probe trigger must be inhibited through software during change cycles using the MCR20.
The above data applies for test conditions as follows:
Brand: Renishaw
TP20 probe body
The TP20 probe body houses one half of the highly repeatable magnetic kinematic coupling that attaches the stylus module and body. The body also contains a magnetic proximity switch to inhibit triggering of the probe during automatic module changing with MCR20.
Note: If the probe is operated close to magnetize parts/clamping etc, the probe trigger may become inhibited. Countermeasures include the use of long styli, stylus extensions or body orientation to increase the distance to the magnetic source. Alternatively, use the TP20 NI probe body.
TP20 NI probe body
The TP20 NI probe differs from the TP20 body in that it is not affected by magnetic fields. However, the probe trigger must be inhibited through software during change cycles using the MCR20.
Specification Summary | TP20 | TP20 NI | |
Principal application | DCC and manual CMMs suitable for most applications | DCC and manual CMMs where operation is within a magnetic field | |
Sense directions |
All modules except 6W 6W |
±X, ±Y, ± Z ±X, ±Y, ± Z |
±X, ±Y, ± Z ±X, ±Y, ± Z |
Pre-travel variation |
LF SF/EM1/EM2 MF EF 6W |
±0.6 μm (±0.000023 in) ±0.8 μm (±0.000032 in) ±1.0 μm (±0.000039 in) ±2.0 μm (±0.000079 in) ±1.5 μm (±0.000058 in) |
±0.6 μm (±0.000023 in) ±0.8 μm (±0.000032 in) ±1.0 μm (±0.000039 in) ±2.0 μm (±0.000079 in) ±1.5 μm (±0.000058 in) |
Repeatability of stylus change (max) |
With SCR 200 Manual |
±0.5 μm (±0.000020 in) ±1.0 μm (±0.000040 in) |
±0.5 μm (±0.000020 in) ±1.0 μm (±0.000040 in) |
Stylus range | M2 | M2 | |
Probe mounting method | M8 thread | M8 thread | |
Suitable interface | PI 4-2, PI 7-2, PI 200 | PI 4-2, PI 7-2, PI 200 | |
Stylus module changing rack (automatic) | MCR 20 | MCR 20 | |
Stylus module storage rack (manual) | MSR1 | MSR1 |
Module type and test stylus length | Trigger Force | Overtravel Force | Overtravel Displacement | Unidirectional repeatability 2σ at stylus tip | 2D (XY) form error | |||||
XY | Z | XY | +Z | -Z | XY | +Z | -Z | |||
SF (black cap)
10 mm
|
0.08 N | 0.75 N | 0.2-0.3 N | 3.5 N | - | ±14° | 4.0 mm (0.16 in) | - | 0.35 μm (0.000014 in) |
±0.8 μm (±0.000032 in) |
LF (green cap) 10 mm |
0.055 N | 0.65 N | 0.09 N | 1.15 N | - | ±14° | 3.1 mm (0.12 in) | - | 0.35 μm (0.000014 in) |
±0.6 μm (±0.000024 in) |
MF (grey cap) 25 mm |
0.1 N | 1.9 N | 0.2-0.4 N | 7.0 N | - | ±14° | 3.7 mm (0.15 in) | - | 0.50 μm (0.000020 in) |
±1.0 μm (±0.000039 in) |
EF (brown cap) 50 mm |
0.1 N | 3.2 N | 0.2-0.5 N | 10.0 N | - | ±14° | 2.4 mm (0.09 in) | - | 0.65 μm (0.000026 in) |
±2.0 μm (±0.000079 in) |
6W (blue cap) 10 mm |
0.14 N | 1.6 N | 0.25 N | 2.5 N | 9.0 N | ±14° | 4.5 mm (0.18 in) | 1.5 mm (0.059 in) | 0.80 μm (0.000032 in) | ±1.5 μm (±0.000059 in) |
EM1 10 mm |
0.08 N | 0.75 N | 0.2-0.3 N | 3.5 N | - | ±14° | 4.0 mm (0.16 in) | - | 0.35 μm (0.000014 in) |
±0.8 μm (±0.000032 in) |
EM2 10 mm |
0.08 N | 0.75 N | 0.2-0.3 N | 3.5 N | - | ±14° | 4.0 mm (0.16 in) | - | 0.35 μm (0.000014 in) |
±0.8 μm (±0.000032 in) |
The above data applies for test conditions as follows:
- Stylus length as states above.
- Stylus velocity 480 mm/min (1.57 ft/min)