NOVOTEST - Ultrasonic Flaw Detector
Previous | 24 / 24 | Next |
NOVOTEST - Ultrasonic Flaw Detector
Brand: Novotest
Model: Novotest UD2301
Advantages:
Specifications:
Brand: Novotest
Model: Novotest UD2301
Advantages:
- Superbright display with which it is comfortable to work outdoors on a sunny day;
- Frequency range from 0 to 10 MHz, with smooth adjustment;
- Display of a scale of scanning in microseconds and millimeters;
- Construction and processing A-scan and B-scan;
- The presence in the device of the operating mode of the DAC curves (construction of 16 points);
- Existence in the device of TVG mode (construction of 16 points);
- DGS function, with automatic calculation of the equivalent reflector size;
- Archive of measurements, settings, transducers with the ability to transfer data to a PC;
- Any side display orientation options that allow user to work in any position of the device;
- The device operates on standard AA batteries, as well as on conventional batteries, which makes them easy to replace;
- The NOVOTEST UD2301 flaw detector can be powered by a universal mobile battery (power bank) via a mini USB connector;
- Ergonomic shockproof case with protective rubber protectors;
- Light weight and compact size.
Specifications:
Operating frequency range | from 1 to 10,0 MHz |
Range of measured time intervals (duration of scanning) | from 6 to 1000 µs |
Velocity range | 1000 – 9999 m / s |
Error of measurement of time intervals | not exceed ± 0,025 µs |
Maximum permissible error of measurement of the amplitudes of the signals at the receiver input in the range from 0 to 110 dB | not exceed ± 0,5 dB |
Testing gain range | 125 dB |
Averaging over the quantity of starts | from 1 to 16 |
Range of variation of temporal sensitivity adjustment (TVG) | 40 dB |
Number of control points TVG | 16 |
Duration of the excitation pulse to the load | from 0,0 to 0,5 µs |
Deviation of the amplitudes of input signals in the range from 10 to 100% of the screen height not more than | 1 dB |
Setting a delay in the prism of the probe | from 0 to 15 µs |
Detection of signals | positive half-wave, radio mode |
Dimensions (W*H*L) | 80*162*38 mm |
Weight, not more | 250 g (without batteries) |