WIKA - Bourdon Tube Pressure Gauge
Previous | 40 / 43 | Next |
WIKA - Bourdon Tube Pressure Gauge
Brand: Wika
Model: PGS23.100
*with switch contacts for the process industry
Standard version:-
1) Nominal size in mm
100, 160
2) Accuracy class
1.0
3) Scale ranges
0 … 0.6 to 0 … 1,600 bar; or all other equivalent vacuum or combined pressure and vacuum ranges
4) Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
5) Permissible temperature
Ambient: -20 … +60 °C for unfilled instruments or instruments with silicone oil filling
Medium: +200 °C maximum with unfilled instruments +100 °C maximum with
filled instruments
6) Temperature effect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
7) Process connection
Stainless steel 316L; Lower mount (radial) / lower back mount; G ½ B (male), SW22
8) Pressure element
Stainless steel 316L; C-type or helical type
Brand: Wika
Model: PGS23.100
*with switch contacts for the process industry
Standard version:-
1) Nominal size in mm
100, 160
2) Accuracy class
1.0
3) Scale ranges
0 … 0.6 to 0 … 1,600 bar; or all other equivalent vacuum or combined pressure and vacuum ranges
4) Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
5) Permissible temperature
Ambient: -20 … +60 °C for unfilled instruments or instruments with silicone oil filling
Medium: +200 °C maximum with unfilled instruments +100 °C maximum with
filled instruments
6) Temperature effect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
7) Process connection
Stainless steel 316L; Lower mount (radial) / lower back mount; G ½ B (male), SW22
8) Pressure element
Stainless steel 316L; C-type or helical type