LINSHANG 每 LS117 Optical Density Meter

Previous 33 / 35 Next


Demonstrate - LS117 Optical Density Meter
LS117 Optical Density Meter
Brand: LinShang
Model: LS117 


 
Main Application :

  • Suitable for testing opalescent translucent materials, example like:  aluminized film, film, X-ray film, lens ink and other materials
  • Visible light transmittance and optical density can be measured simultaneously
  • Measuring accurately, and ensure it can pass the inspection of Chinese national authoritative metrology institute.
  • The optical density meter is suitable for testing the light transmittance of opalescent translucent materials, matte materials.
 
Product Introduction:
LS117 densitometer is an instrument that can measure both optical density and light transmittance. The instrument adopt the diffuse transmission principle which is suitable for the optical density test of opalescent translucent materials and frosted matte materials. The light source of the instrument complies with the CIE photopic luminosity function and can pass the inspection of Chinese national metrological institute.
 
Specification:

Parameter Value
Light transmittance measurement accuracy ±1% (0%-50%)
±2% (50%-100%)
Light transmittance resolution 0.0005% (0%-10%)
0.005% (10% -100%)
Optical density measurement range 0.000OD-6.000OD
Optical density measurement accuracy ±0.02 (0-2.00OD)
±2% (2.00-6.00OD)
Optical density resolution 0.001 OD (0.00-2.00OD)
0.01 OD (2.00-4.00OD)
0.1 OD (4.00-6.00OD)
Aperture 2mm
Light Source 380nm-760nm, conforming to CIE photopic luminosity function
Weight About 576g (without battery)
Power supply 4*AAA alkaline dry battery
Display 240*160 dot-matrixes LCD
Dimension 148mm×76mm×26mm (L*W*H)
 
 
 Features:
 
High resolution, wide optical density measurement range
The optical density meter has wide measuring range. The optical density value can be measured to OD 6. The transmittance resolution is up to 0.005%
 
 
Light transmittance and optical density are measured simultaneously
During the test, the interface displays both the transmittance value and the optical density value of the material
 


 

 
Diffuse transmission light path design
The LS117 portable densitometer uses a diffuse transmission light path design, which has the same effect of the integrating sphere. There are relevant instructions in ''GB / T 11500-2008 / ISO 5-2: 2001''. The regulation has stated that “Use opale glass method instead of integrating sphere method as the basis of ISO standard diffuse transmission density''
 


 
 
High-precision and great accuracy
The light source complies with the CIE photopic luminosity function to ensure that it passes by the calibration lab of the Chinese Metrology Institute which certify under CNAS & IEC 17025.
 


 

 
 
Two measurement ways for more flexible to use
The optical density meter has two measurement methods which is more flexible to use.
Fixed measurement: It is more suitable for testing regular or smaller objects.
Hand-held measurement: take the probe down for testing, which is more suitable for irregular and large-volume materials


 
 
 
 
 