Advantages:

  • Small indenter imprint (suits for mirror surfaces of shafts necks, blades, gear teeth, etc.)
  • Measuring surface hardened layers hardness
  • Wide range of hardness testing
  • Various measurement modes
  • 88 combinations of materials and hardness scales (calibrations)
  • Calibration of any scale in any range
  • Convenience and ease of measurement
  • Optimized number of buttons
  • Large full-color graphic display with bright backlight
  • Built-in photo camera for thorough reports
  • Automatic probe types recognition
  • Connected probe types indication
  • The calibrations are stored in UCI probe memory
  • Extended operating temperature range (frost, down to – 40°C)
  • Internal memory and communication with a PC
  • New intuitive menu with tips on the buttons
  • Optional wireless mini printer
  • Waterproofed housing
  • Rubber bumper protected housing
  • Internal clock
  • Hardness value measuring for any mass products with more than 1 mm  thickness (small parts, thin-walled structures, pipes, tanks, steel sheets, articles of complex shape, hardness testing of metal coatings, etc.)
  • Different operating modes
  1. Graph – the graph building mode
  2. Histogram – the histogram building mode
  3. Statistics – provides statistics for the current set of measurements
  4. Smart – filters the incorrect measurements
  5. Signal – displays the probe signal (only for the Leeb probe)

Specifications:
UCI probe types 1kgf (10N) 2.2 lbf
5kgf (50N) 11lbf
10kgf (98N) 22lbf
Leeb probe types D
DC
DL
C
D+15
E
G
Measuring range HRC:20~70
HB:90~650
HV:230~940
Tensile strength, MPa: 370~1740
User calibrations for any range (for example: HV100-1600)
Measuring accuracy HRC: 2HRC
HB: 10HB
HV: 15HV
Standards ASTM A1038
ASTM A956
ASTM E140
Indenter UCI probe – Diamond indenter
Leeb probe – Hardened ball
Measuring direction Any direction 360°
Data storage Limited only by the memory card up to 32Gb
Communication Upload data to PC and export as a spreadsheet (USB cable and software included )
Hardness scales UCI probe – HRC, HB, HV
Leeb probe – HRC, HRB, HB, HV, HL, MPa
Additional custom scales for calibration
Materials Ultrasonic (UCI) probe – pre-calibrated for steel
Dynamic (Leeb) pre-calibrated for steel, alloy steel, cast iron, stainless steel, aluminum, bronze, brass, copper
Additional custom materials for calibration
Data display Load applied/contact (UCI)
Angle (Leeb)
Single test result
Max, Min, Average of tests
Number of tests,
Deviation
Var. coeff.
Histogram, Signal and Smart Modes (Filter of incorrect measurements).
Indication Color LCD display (320×240)
Operating environment Temperature:-20°C~40°C
Humidity: 30%~80%R.H.
Power supply DC 4,5V (3 pcs batteries AA)
Instrument dimensions 160x75x30mm
Net weight Approx. 0.3kg (without probe)
Gross weight (package) 2kg
Battery life Approx. 10 hours.
Warranty 3 (1+2) years


Available Options:
  • Additional UCI and Leeb probes (different types)
  • Different colors of rubber bumper protected case
  • Wireless printer
  • Batteries
  • Chargers
  • Hardness tests blocks
  • Set of support rings for D, DC type Leeb probes
  • Impact bodies for Leeb probes
  • Portable grinding machine
  • Case for hardness tester
  • Can be equipped with three types of UCI probes:
98N(10 kgf) Special type of probe with increased load. To carry out the measurement, it is necessary to apply a load of 10 kgf (set automatically by the probe).Low surface cleanliness requirements.
  • Heat-treated and cemented parts with poorly prepared surface.
  • Measurement on blades, on the inner surface of pipes, holes with high roughness.
50 N(5 kgf) The main type of probe for solving most hardness measurement tasks. To carry out the measurement, it is necessary to apply a load of 5 kgf (set automatically by the probe).Medium surface cleanliness requirements.
  • Heat-treated and cemented parts, such as shafts, turbines, gears, teeth, welds, heat affected zones.
  • Measurement in grooves, on teeth, in grooves, on radius surfaces.
  • Measurement on the blades, on the inner surface of the pipes, holes.
10 N(1 kgf) Probe with reduced load – designed to measure the hardness of products with increased requirements for the size of the print (polished, polished surfaces), to measure the hardness of thin surface hardened layers. For the measurement, a load of 1 kgf must be applied.More demanding on surface cleanliness, compared with U1 (50N).
  • Nitrided and cemented surface layers of molds, dies, dies, thin-walled parts.
  • Bearings, tooth flanks, saws.
  • Hardness measurement of thin hardening coatings.
  • Measurement on products after thorough machining.


Standard Package:
  • Hardness tester
  • UCI probe (10N, 50N or 98N for choice)
  • 3pcs AA batteries
  • Charger
  • USB cable
  • Operating manual
  • Software for PC
  • Case