- Color & Paint Coating Measurement
- Dimensional Measurement
- Electrical & Electronic Meter
- Electrostatics (ESD) , Ionizer & Resistivity Meter
- Environmental & Weather Aging Testing
- Gas Measurement
- Handling & Cutting Tools
- Hardness Testing
- Laboratory Equipments
- Levelling Angle Gauges
- Magnetic Testing
- Medical Equipment
- Metallography
- Microscope, Magnifier & Visual Inspection
- Paper & Film Packaging Testing
- Pressure & Flow
- Rubber & Glove Testing
- Storage Dry Cabinet
- Temperature, Humidity & Moisture
- Tensile & Tension Torque/Force
- Ultrasonic NDT Testing
- Vise & Holder
- Water Analysis Meter
- Weighing
- Others
KANOMAX - Handheld Gas Monitor 2700 Series 2710 2750
Previous | 16 / 22 | Next |
KANOMAX - Handheld Gas Monitor 2700 Series
Brand : Kanomax
Model : 2710 , 2750
Description :
Gasmaster Handheld gas monitors are suitable for indoor, industrial and outdoor air quality monitoring. Compatible with over 20 different interchangeable sensor heads, one monitor can be used to measure multiple gases and concentrations. Interchangeable sensor heads also make servicing the monitors as simple as replacing the old head with a new one.
The 2700 series of Kanomax Gas Monitors can be configured with a wide range of single or multi-gas sensor heads. Each sensor head is simply plugged into the detector to begin monitoring. The detector does not require additional configuration allowing sensor heads to be swapped out easily in the field.
Specification :
Brand : Kanomax
Model : 2710 , 2750
Description :
Gasmaster Handheld gas monitors are suitable for indoor, industrial and outdoor air quality monitoring. Compatible with over 20 different interchangeable sensor heads, one monitor can be used to measure multiple gases and concentrations. Interchangeable sensor heads also make servicing the monitors as simple as replacing the old head with a new one.
The 2700 series of Kanomax Gas Monitors can be configured with a wide range of single or multi-gas sensor heads. Each sensor head is simply plugged into the detector to begin monitoring. The detector does not require additional configuration allowing sensor heads to be swapped out easily in the field.
Specification :
Model | 594-MR (high-voltage power supply)/GI-04B (air gun) |
Ion generation method | AC corona discharge |
Discharging electrode needle | Stainless |
Recommended air pressure | 0.2-0.4 MPa |
Amount of air consumption | 150-300 L/min |
Amount of zone production | 0.02 ppm or less (150 mm) |
Operating environment | Temperature : 0°C - 40°C, Humidity : 80 % RH or below (no condensation) |
Input condition | AC 100 V 50/60 Hz |
Consumption current | Approx. 15VA |
Mass | 594-MR : Approx. 4.8kg, GI-04B : Approx. 500 g |