Ozone Aging Test Chamber
Previous | 37 / 38 | Next |
Ozone Aging Test Chamber CY013
Model: CY013
Use conditions:
Technical Indicators:
This series of test cases of ozone produced by ozone generator can be used in the nonmetallic material, organic material, coating, rubber, plastic, paint, paint, etc.) Under the condition of the ozone ageing test.
1. Internal chamber size (mm): 400 * 400 * 500
2. Ozone concentration: 25 ~ 500 PPHM (adjustable)
3. Deviation of ozone concentration: ≤5%
4. Laboratory temperature: RT + 10 ˚ ~ 60 ˚C
5. Temperature fluctuation degree: ±0.5˚C
6. Evenness±2˚C
7. Test gas flow: 20~80L/min
8. Test device: static
9. Sample holder speed: 360 rotary racks (speed 1 revolutions per minute)

10. Ozone source: ozone generator
11. Sensor: British import ozone concentration sensor, can achieve precise control
12. PLC controller

13. Main control interface

14. Standard: GB/T7762-2003, ASTM1149 ,ISO1431,GB/T136421-92,HG/T2869-97
Power:
Model: CY013
Use conditions:
- Ambient temperature: 0 ˚C ~ 35 ˚C
- Pressure: standard atmospheric pressure
- Relative humidity: ≤90%RH
- Power: 220V±10%
Technical Indicators:
This series of test cases of ozone produced by ozone generator can be used in the nonmetallic material, organic material, coating, rubber, plastic, paint, paint, etc.) Under the condition of the ozone ageing test.
1. Internal chamber size (mm): 400 * 400 * 500
2. Ozone concentration: 25 ~ 500 PPHM (adjustable)
3. Deviation of ozone concentration: ≤5%
4. Laboratory temperature: RT + 10 ˚ ~ 60 ˚C
5. Temperature fluctuation degree: ±0.5˚C
6. Evenness±2˚C
7. Test gas flow: 20~80L/min
8. Test device: static
9. Sample holder speed: 360 rotary racks (speed 1 revolutions per minute)

10. Ozone source: ozone generator
11. Sensor: British import ozone concentration sensor, can achieve precise control
12. PLC controller

13. Main control interface

14. Standard: GB/T7762-2003, ASTM1149 ,ISO1431,GB/T136421-92,HG/T2869-97
Power:
- The rated power: 4.5 KW
- Power supply: AC220V±10%, 50HZ
- Machine noise: ≤70dbA